What is LPO? Linear drive and pluggable optics
LPO usually means Linear Pluggable Optics and is also described as Linear-drive Pluggable Optics. It is an optical interconnect architecture, rather than a new mechanical form factor alongside QSFP-DD or OSFP. Its defining feature is a linear high-speed data path that removes the module DSP and retiming functions, placing greater responsibility for equalization and signal recovery on the host SerDes.
Pluggable modules fit into front-panel ports on switches, network adapters or other equipment and connect to optical fiber. They can be replaced using the supported service procedure. Conventional optics are also pluggable, so the key distinction is signal processing inside the module. Hot-plug operation must still be supported by the particular module and host.
Understanding DSP and CDR through the signal path
An optical module converts electrical signals into light and converts received light back into electrical signals. A simplified transmit path consists of the host SerDes, an electrical channel, module processing circuitry, a laser driver and a laser or modulator. The receive path includes a photodetector, transimpedance amplifier (TIA), processing circuitry and the host SerDes. The exact partition depends on the rate, optical technology and architecture.
A digitally processed implementation may use a DAC to generate a transmit waveform and an ADC to sample a received waveform, with DSP performing equalization, timing recovery, lane mapping or other processing. Those converters are not necessarily both inside the optical module. Lower-rate modules, discrete-CDR designs, DSP-based PAM4 modules and coherent optics do not all share one universal block diagram.
A DSP runs signal-processing algorithms that compensate for some channel impairments and improve symbol decisions; it may also implement gearbox functions. CDR recovers timing from incoming data and, in a retimed design, resamples the output. Coherent DSPs can additionally address dispersion and polarization, but those functions should not all be attributed to short-reach direct-detection modules. DSP cannot remove every source of noise or reconstruct information that has been irretrievably lost.
How LPO removes the module DSP
Fully linear LPO omits a separate DSP retiming stage from the module high-speed data path. Host transmit conditioning, receive equalization and timing recovery work with high-linearity, low-noise drivers and TIAs to recover data across the complete electrical and optical channel. The module still needs its optical transmitter, detector, power circuitry and management controller; it does not consist of just two chips.
Drivers, TIAs or associated circuitry may provide continuous-time linear equalization (CTLE), other equalization and gain control, depending on the implementation. Those functions need not all be integrated into one device. The linear path must preserve PAM4 amplitude information; the hard-limiting behavior of a conventional limiting amplifier is not a direct substitute.
This is a repartitioning of link processing, rather than moving every function of an existing module DSP unchanged into a switch chip. Host SerDes capabilities, board traces, connectors and optics must be engineered together. Half-retimed approaches such as linear receive optics (LRO) should be distinguished from fully linear LPO. Required FEC normally remains in the relevant host protocol layer and does not automatically disappear when the module DSP is removed.
Power, cost and latency: measuring the benefits
Removing the module DSP and supporting circuitry can reduce module power, heat, processing latency and some material costs. This is attractive in dense AI networks. Comparisons should nevertheless include host SerDes, optics, FEC and cooling: module power savings do not translate directly into the same percentage of switch power savings, and reduced module latency is not an equivalent reduction in application latency.
In a 2023 example, MACOM reported that DSP-based 800G multimode modules could consume more than 13 W, compared with less than 4 W for 800G multimode modules using its PURE DRIVE technology. This is a vendor example for particular technology and module conditions, not a universal rating for all 800G optics or a figure that can be transferred to single-mode products, other reaches or newer generations.
Cost savings must be evaluated against the actual BOM, purchasing volume and qualification effort. Removing DSP and supporting components saves some module costs, but a linear analog front end, host design and integration also carry costs. Unqualified claims of a fixed DSP cost percentage or a fixed dollar saving per module should not be used as general procurement assumptions.
Comparing LPO, retimed optics and CPO
Conventional DSP-based pluggables provide module-side processing and retiming that can help isolate some host-channel impairments within specified limits. They do not guarantee compatibility with every platform, but they generally offer additional processing resources for managing link margin and defining a module qualification boundary.
LPO retains the front-panel pluggable format while changing signal-processing partitioning. Co-packaged optics (CPO) integrates optical engines with the switching ASIC in a common package or tightly integrated package assembly to shorten electrical connections. Simply placing optics nearby may instead describe NPO or another architecture. LPO describes processing behavior; CPO describes integration and placement, so DSP presence alone does not define the distinction.
LPO normally preserves individual module replacement. CPO optical engines are generally not removable like front-panel pluggables, but serviceability depends on the platform; some designs provide replaceable external laser sources or other serviceable parts. It is therefore inaccurate to claim that every CPO component failure necessarily requires powering down and replacing the entire board.
Reach, interoperability and deployment requirements
LPO targets jointly engineered and qualified datacenter links, including intra-rack, inter-rack and single-mode connections covered by the relevant specifications. Removing module retiming changes the equalization and noise budget, but does not inherently mean an unacceptable error rate or impose one universal reach limit. Reach depends on the optical PMD, fiber, connector loss, electrical channel, host SerDes and FEC margin.
Qualification should identify the host, ASIC and SerDes settings, software, module specification, channel loss, fiber, connectors, temperature and acceptance criteria. Check pre-FEC errors, uncorrectable errors, sustained traffic, neighboring-port heat, startup and restart, insertion, alarms, batch variation and replacements. A link-up indication alone does not establish reliability.
Multi-vendor interoperability requires specifications and test evidence. Defining electrical and optical requirements for a compatible ecosystem is a purpose of the LPO MSA, so LPO should not be defined as inherently limited to closed or single-supplier systems. Procurement should confirm specification revisions, platform support, interoperability results and responsibility for investigating host, module and cabling issues.
224G SerDes: an engineering challenge, not an absolute barrier
Higher lane rates tighten bandwidth, noise, linearity and channel-loss budgets, increasing demands on packaging, analog components and host equalization. However, the claim that LPO cannot support 224G SerDes is no longer an appropriate blanket conclusion. On March 16, 2026, Semtech announced 224 Gbps-per-lane TIAs and drivers targeting LPO and related architectures.
A component announcement does not qualify every 224G platform or 1.6T module. Buyers still need to verify component and module availability, applicable specifications, target hosts and long-duration results. As of October 20, 2026, 224G linear optics is advancing, while deployment readiness remains specific to the platform and link.
Sources and selection guidance
This guide draws on the LPO MSA architecture and interoperability objectives, MACOM’s historical power example and Semtech’s 224G component announcement. Evaluate the host, module, cabling and qualification plan as a complete system. Share the required rate, reach, host and software with the supplier before confirming a product configuration and acceptance plan.
Frequently Asked Questions
Can LPO directly replace conventional DSP-based modules?
Matching form factor and rate is not enough. The host SerDes must support the intended linear link, with suitable electrical channel loss, optical interfaces, FEC and software settings. Qualify samples and interoperability on the target platform before approving volume replacement.
Does LPO still require FEC after removing the DSP?
Usually, yes. Removing module-side DSP retiming does not automatically remove FEC from the host protocol layer. Configure the FEC mode required by the optical interface and host, and assess pre-FEC errors, uncorrectable errors and sustained service traffic during qualification.
Is LPO limited to a reach of only a few meters?
No. There is no single reach limit for all LPO products; implementations can support multimode or single-mode links covered by the relevant specifications. Actual reach depends on the optical specifications, fiber and connector losses, host SerDes and complete link margin. Use the specific product data sheet and system test results.
What information should buyers provide before sourcing LPO modules?
Provide the host model, ASIC or SerDes details, software version, target rate, form factor, optical interface, fiber type, reach, connectors, temperature range and quantity. Also confirm specification revisions, platform support, test reports and acceptance criteria so the supplier can verify the configuration and plan qualification.
Need help selecting a compatible transceiver?
Tell us your target platform, data rate, fiber type, and transmission distance.